The insulating flange connection type 61 is used as an electrotechnical protective measure to safely interrupt the metallic conductivity of a flange connection or a cathodic corrosion protection system (CCP system) and also to protect against bimetal corrosion.
Type 61D Outer diameter = flange diameter + 60 mm > Prevents unwanted bridging
Type 61L Through holes for insulating bolts + 5 mm > Simplified assembly of the screw bolts
Type 61A Coating for aggressive media > Use with aggressive media
Product info
INSULATING FLANGE
TYPE: 61D
Nominal diameter (DN): 100
Nominal pressure (PN): 16
Operating temperature range (TS): -20 to +60 °C
Pressure stage (PS): 16 bar (g)
Permissible torque (Mzul): 97 Nm
Gas expansion turbine
Nominal diameter: DN 400
Design printing: DP 16
Volume flow: 1500 – 8000 Nm³ / h
Electrical power: 15-30 KW
Pressure loss: 0.5 – 1.5 bar
Temperature drop: 5 – 10 °C
Overall length: approx. 670 mm
Weight: approx. 375 kg
Components - Material - Standard
1st bolt – 25CrMo4 – DIN 2510 Form L
2.Nut – 25CrMo4 – DIN 2510 Form NF
3.Cable lug / washer – steel 200HV
4.Insulating disk
5.Comb profile seal
6.Insulating ring
The working method
The insulating flange connection is designed in such a way that it can withstand the usual loads once it has been properly installed and is fully functional The insulating flange connection type 61 is easy to install, maintenance-free, technically tight and meets the current state of the art.
The W2 media service
Via our W2 media service you can access all relevant View initial information online.
Data sheets
Further information about our products can be
You can download here.